- This manual is written for the C2150 control with Version 1 software which is used in the controls of the 2000 series linear drive operators. The C2150 control receives its power from a separate power supply (usually a C3955) which provides +27 to +35 VDC to power all of the accessory devices as well as power for the control itself.
- Horton K2176-5 Fail Secure Autolock Kit For C2150 Control 2000 Linear Drive Automatic Sliding Door - Duration: 0:35. Automatic Door and Hardware 46 views.
- Dec 01, 2017 Horton K2176-5 Fail Secure Autolock Kit For C2150 Control 2000 Linear Drive Automatic Sliding Door - Duration: 0:35. Automatic Door and Hardware 46 views.
EAGLE
USER GUIDE
1 Description
Terminal | Narrow Antenna Storage | Linux mint create shared folder for mac 2017. Manual Set-Up Buttons | Wire Opening Knockout | Opening Tab |
Block | (inside the cover) |
Wire Passage Hole | Planar Antenna | Lateral and Angle | Front Cover | LED |
Adj. For Antenna |
NOTE: For mounting heights between 10’ and 16’, use BEA model 10EAGLEHM (high mount).
![Horton Horton](https://usersmanuals1.com/uifiles/62/189768/horton-c2150-manuals_n.png)
2 | Technical Specifications | |
DESCRIPTION | SPECIFICATION | |
Frequency: | 24.125 GHz | |
Supply voltage: | 12 to 24 V AC: ± 10%: | |
12 to 24 V DC: -10% / +30%: | ||
Mounting height: | Normal: 7’; Maximum: 10’-0” | |
Tilt angle: | 0° to 90° vertical | |
-15° to +15° lateral | ||
Detection area: | 13ft (W) x 6.5ft (D) | |
Wide | ||
6.5ft (W) x 8.2ft (D) (supplied as optional) | ||
Minimum detection speed: | 2 in/sec. (measured in axis) | |
Power consumption: | < 2 W | |
Standard output relay: | ||
Max contact voltage | 60 VDC / 125 VAC | |
Max contact current | 1 A (resistive) | |
Max switching power | 30W (DC) / 60VA (AC) | |
Hold time: | 0.5 sec. to 9 sec. (adjustable) | |
Temperature range: | -4°F to 131°F | |
Dimensions: | 4.75in (W) x 3.15in (H) x 2.0in (D) | |
Weight: | 0.5lbs | |
Material: | ||
Housing color: | Black. Can be painted with non-metallic paint | |
Cable length: | 6ft |
75.5185.04 20070727 | Page 1 of 8 |
1 Tips
The sensor must be firmly fastened to prevent vibration.
The sensor must not be placed directly behind a panel or any kind of material.
The sensor must not have any object likely to move or vibrate in its sensing field.
The sensor must not have any fluorescent lighting in its sensing field.
Horton C2150 Controller Programming Manual Software
2 Safety Precautions
•Shut off all power going to the header before attempting any wiring procedures.
•Maintain a clean & safe environment when working in public areas.
•Constantly be aware of pedestrian traffic around the door area.
•Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
•Always check placement of all wiring and components before powering up to insure that moving door parts will not catch any wires and cause damage to equipment.
•Ensure compliance with all applicable safety standards upon completion of installation.
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
Circuit board components are vulnerable to damage by electrostatic discharge (ESD). ESD can cause immediate or subtle damage to sensitive electronic parts. An electrostatic charge can build up on the human body and then discharge when you touch a board. A discharge can be produced when walking across a carpet and touching a board, for example. Before handling any board, make sure you dissipate your body’s charge.
Horton C2150 Controller Programming Manual Online
CAUTION: In the event a unit needs to be opened, observe the following precautions.
Ground yourself by touching a conductive surface of the door or other element connected to common earth ground to discharge the static electricity present in your body.
Avoid walking around while replacing items inside the case, especially if you are on carpet or during conditions of low temperature and low humidity.
Handle the board by the edges only to avoid touching electronic components. Store a loose board in an anti-static bag.
3 | Mechanical Installation |
Opening the sensor | |
From behind, before installation | From the front, after installation |
Mounting the sensor
or | ||||
Paste the template at desired | Insert screws but do not screw | Optional cable routing: | ||
Us army great skills program. location. | them fully in. | Notch the cover as shown in | ||
Drill as instructed. | Pass the cable where | the picture. | ||
indicated. |
4 | Electrical Installation | ||||||||
Terminal | Connection | ||||||||
1 | (Red) | 12 to 24 | VAC / DC (+) | ||||||
2 | (Black) | 12 to 24 | VAC / DC (-) | ||||||
3 | (White) | Relay Common | |||||||
4 | (Green) | Relay N.O. | |||||||
5 | Relay N.C. | ||||||||
Note: Input power | tolerance is +/- 10% for | ||||||||
AC, and -10% to +30% for DC power. |
Run the cable through the wire | Position the sensor and tighten the | Wiring connections are as shown above. |
passage hole just below PCB. | two screws. Make sure you leave | |
enough cable to reach the terminal | ||
block near the top of the sensor. |
75.5185.04 20070727 | Page 3 of 8 |
C Video Instructions. Horton Automatics; 12 videos; 13, views; Last updated on Jul 18, Play all. Share. Loading Save. Horton Automatic sliding door systems are used in a wide range of commercial and industrial applications. The breadth of this product offering from Horton. Find great deals for Horton Automatics C Control Module Automatic Door. Shop with confidence on eBay!.
Author: | Mazum Maull |
Country: | Turkmenistan |
Language: | English (Spanish) |
Genre: | Travel |
Published (Last): | 28 May 2018 |
Pages: | 374 |
PDF File Size: | 12.57 Mb |
ePub File Size: | 19.72 Mb |
ISBN: | 409-3-17543-283-2 |
Downloads: | 57699 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Yole |
Autolock has failed to unlock see sect 8 2.
Horton Automatics, Sliding Door Systems
Darkroom booth keygen torrent. Close braking can be turned on at the [b parameter 2. Each segment of 4 for a total of 8 segments should appear. Enter text from picture: In case of difficulty Trouble shooting the C ……………………….
Belt drive function test………………. In Case Of Difficulty trouble Shooting The C -If the fuse does not blow,reconnect the power harness at CN7 and attempt to operate the door with the motor unplugged. Don’t show me this message again.
If anything occurs other than the description shown above the C will get improper If the encoder fails replace the entire unit. To print the manual completely, please, download it. The C display will flash bF until the failure is Yellow corrected.
Power Failure Units Fail reset Failure -If the batteries test fails during daytime operation it wil go to full open position as per 1. Yellow See diagram 2 page C1250 Mount the partial open switch at the -A blank display means that the door is in mid-stroke no switches are tripped. Related Manuals for Horton C No related manuals. Test -To maintain security,battery failures are ignored in the night mode,but the failure hoorton stored on the units circuit board.
Actuation Features During initialization the control clears all ports and the solenoid becomes inactive. Got it, continue to print. Table Of Contents Micro Switch Hodton -Missing codes, or codes that appear in improper order, indicate a problem with a switch assembly or a defective switch lace, or possibly the C Also See for C Setup instructions – 12 pages.
HORTON C SETUP & TROUBLESHOOTING Pdf Download.
Encoder Error Codes Each segment of 4 for a total of 8 segments should appear. Do not leave this adjustment at minimum. No segment hroton be skipped. During initialization the control clears all ports and the solenoid becomes inactive. Page 19 Autolock has failed to unlock see sect 8 2. By pressing ‘print’ button you will print only current page. Comments to this Manuals Your Name. Horton recommends setting Partial Open stroke in inches the sensitivity so the door will reverse at 28 ft.
Page of 23 Go. Code displays, foot notes and short cuts…… ……………………….
Horton Automatics reserves the right to improve the product and change its specifications without notice. Adjusting Parameters procedure For Changing Preset Parameters 4 reserved parameters c210 the reversing sensitivity as required using R There are no serviceable elements on the C Actuation Features Yellow See diagram 2 page H Table of Contents Add to my manuals Add. Linear drive function test……………………………………………………H Don’t have an account?
Inspect the unit for smooth operation, free of binds and excessive noise. The chart following shows the position of the door and the display code for each position. Troubleshooting Setting lock parameters C Initialization learn Cycle Cont The chart following shows the position of the door and the display code for each hortob.